New user? / Forgot your password?
0 Item | 0,00 €
Item number | 685547 |
CAS | 1173020-20-6 |
Formula | C3HCl2D5O |
Molecular weight | 134,02 g/mol |
Quantity | 1X25MG |
storage conditions | 20 °C |
CoA / MSDS | Retrieve CoA Retrieve MSDS |
Product | Catalog No./ CAS No. | Quantity | Price | |
---|---|---|---|---|
677427 | 1X250MG | Please log in. | ||
685547 | 1X25MG | Please log in. |
Safety Data Sheet | according to Regulation (EC) No 1907/2006 (REACH) Classifications according to Regulation (EC) No 1272/2008. Printdate 02.12.2024 |
IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING | |
Product name: | D5-1,3-Dichloropropan-2-ol |
Catalog No.: | 685547 |
Relevant identified uses of the substance or mixture | Identified: Laboratory chemical uses: R&D |
Uses advised against: | HPC Standards GmbH Am Wieseneck 7 04451 Cunnersdorf Deutschland Tel. +49 34291 3372-36 Fax. +49 34291 3372-39 contact@hpc-standards.com |
Emergency telephone number | HPC Standards Tel. +49 34291 3372-36 This number is only available during office hours. |
HAZARDS IDENTIFICATION | 2.1 Classification of the substance or mixture Classification according to Regulation (EC) No 1272/2008 Carcinogenicity (Category 1B), H350 Acute toxicity, Oral (Category 3), H301 Acute toxicity, Dermal (Category 4), H312 |
Label elements | |
Pictogram | GHS06 skull skull GHS08 silhouete silhouete |
2.2 Label elements Labelling according Regulation (EC) No 1272/2008 Pictogram Signal word Danger Hazard statement(s) H301 Toxic if swallowed. H312 Harmful in contact with skin. H350 May cause Cancer Precautionary statement(s) P201 Obtain special instructions before use. P280 Wear protective gloves/ protective clothing. P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/doctor. P308 + P313 IF exposed or concerned: Get medical advice/ attention. Supplemental Hazard Statements none Restricted to professional users. 2.3 Other hazards - none | |
COMPOSITION/INFORMATION ON INGREDIENTS | 3.1 Substances Synonyms : 1,3-Dichloro-2-propanol-d5 Formula : C3HD5Cl2O Molecular weight : 133,92 g/mol CAS-No. : 1173020-20-6 Index-No. : 602-064-00-0 Hazardous ingredients according to Regulation (EC) No 1272/2008 Component Classification Concentration 1,3-Dichloroisopropyl-d5 alcohol CAS-No. Index-No. 1173020-20-6 602-064-00-0 Carc. 1B; Acute Tox. 3; Acute Tox. 4; H350, H301, H312 <= 100 % |
Formula | C3HCl2D5O |
Molecular Weight (g/mol) | 134.02 |
CAS-No. | 1173020-20-6 |
FIRST AID MEASURES | 4.1 Description of first aid measures General advice Consult a physician. Show this safety data sheet to the doctor in attendance. If inhaled If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician. In case of skin contact Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician. In case of eye contact Flush eyes with water as a precaution. If swallowed Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician. 4.2 Most important symptoms and effects, both acute and delayed The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11 4.3 Indication of any immediate medical attention and special treatment needed No data available |
FIRE-FIGHTING MEASURES | 5.1 Extinguishing media Suitable extinguishing media Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide 5.2 Special hazards arising from the substance or mixture Hydrogen chloride gas 5.3 Advice for firefighters Wear self-contained breathing apparatus for firefighting if necessary. 5.4 Further information Use water spray to cool unopened containers |
ACCIDENTAL RELEASE MEASURES | 6.1 Personal precautions, protective equipment and emergency procedures Wear respiratory protection. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas. For personal protection see section 8. 6.2 Environmental precautions Prevent further leakage or spillage if safe to do so. Do not let product enter drains. 6.3 Methods and materials for containment and cleaning up Contain spillage, and then collect with an electrically protected vacuum cleaner or by wet-brushing and place in container for disposal according to local regulations (see section 13). Keep in suitable, closed containers for disposal. 6.4 Reference to other sections For disposal see section 13. |
HANDLING AND STORAGE | 7.1 Precautions for safe handling Avoid exposure - obtain special instructions before use.Avoid contact with skin and eyes. Avoid inhalation of vapour or mist. Keep away from sources of ignition - No smoking.Take measures to prevent the build up of electrostatic charge. For precautions see section 2.2. 7.2 Conditions for safe storage, including any incompatibilities Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Store under inert gas. hygroscopic Storage class (TRGS 510): 6.1B: Non-combustible, acute toxic Cat. 1 and 2 / very toxic hazardous materials 7.3 Specific end use(s) Apart from the uses mentioned in section 1.2 no other specific uses are stipulated |
EXPOSURE CONTROLS/PERSONAL PROTECTION | 8.1 Control parameters Ingredients with workplace control parameters 8.2 Exposure controls Personal protective equipment Eye/face protection Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses Skin protection required Body Protection protective clothing Respiratory protection required when vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type ABEK The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented. Control of environmental exposure Do not let product enter drains. |
PHYSICAL AND CHEMICAL PROPERTIES | 9.1 Information on basic physical and chemical properties a) Appearance Form: liquid Colour: colourless b) Odour No data available c) Odour Threshold No data available d) pH No data available e) Melting point/freezing point Melting point/range: -4 °C - lit. f) Initial boiling point and boiling range 174,3 °C - lit. g) Flash point 85 °C - closed cup h) Evaporation rate No data available i) Flammability (solid, gas) No data available j) Upper/lower flammability or explosive limits No data available k) Vapour pressure No data available l) Vapour density No data available m) Relative density 1,417 g/mL at 25 °C1,417 g/cm3 at 25 °C n) Water solubility No data available o) Partition coefficient: noctanol/ water No data available p) Auto-ignition temperature No data available q) Decomposition temperature No data available r) Viscosity No data available s) Explosive properties No data available t) Oxidizing properties No data available 9.2 Other safety information No data available |
STABILITY AND REACTIVITY | 10.1 Reactivity No data available 10.2 Chemical stability Stable Stable under recommended storage conditions. 10.3 Possibility of hazardous reactions No data available 10.4 Conditions to avoid Heat, flames and sparks. 10.5 Incompatible materials No data available 10.6 Hazardous decomposition products Hazardous decomposition products formed under fire conditions. - Hydrogen chloride gas Other decomposition products - No data available In the event of fire: see section 5 |
TOXICOLOGICAL INFORMATION | 11.1 Information on toxicological effects Acute toxicity No data available Skin corrosion/irritation No data available Serious eye damage/eye irritation Respiratory or skin sensitisation No data available Germ cell mutagenicity Carcinogenicity Possible human carcinogen Reproductive toxicity Specific target organ toxicity - single exposure No data available Specific target organ toxicity - repeated exposure No data available Aspiration hazard No data available Additional Information RTECS: Not available To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated |
ECOLOGICAL INFORMATION | 12.1 Toxicity No data available 12.2 Persistence and degradability No data available 12.3 Bioaccumulative potential No data available 12.4 Mobility in soil No data available(1,3-Dichloroisopropyl-d5 alcohol) 12.5 Results of PBT and vPvB assessment PBT/vPvB assessment not available as chemical safety assessment not required/not conducted 12.6 Other adverse effects No data available |
DISPOSAL CONSIDERATIONS | 13.1 Waste treatment methods Product This combustible material may be burned in a chemical incinerator equipped with an afterburner and scrubber. Offer surplus and non-recyclable solutions to a licensed disposal company. Contaminated packaging Dispose of as unused product |
TRANSPORT INFORMATION | 14.1 UN number ADR/RID: 2750 IMDG: 2750 IATA: 2750 14.2 UN proper shipping name ADR/RID: 1,3-DICHLOROPROPANOL-2 IMDG: 1,3-DICHLOROPROPANOL-2 IATA: 1,3-Dichloropropanol-2 14.3 Transport hazard class(es) ADR/RID: 6.1 IMDG: 6.1 IATA: 6.1 14.4 Packaging group ADR/RID: II IMDG: II IATA: II 14.5 Environmental hazards ADR/RID: no IMDG Marine pollutant: no IATA: no 14.6 Special precautions for user No data available |
REGULATORY INFORMATION | 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006. 15.2 Chemical safety assessment For this product a chemical safety assessment was not carried out |
OTHER INFORMATION | The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. For lab use only! |