D5-1,3-Dichloropropan-2-ol

Item number685547
CAS1173020-20-6
FormulaC3HCl2D5O
Molecular weight134,02 g/mol
Quantity 1X25MG
storage conditions20 °C
CoA / MSDSRetrieve CoA
Retrieve MSDS
D5-1,3-Dichloropropan-2-ol

Price

Please log in.

Part of Product groups:
Product Variations:

Product

Catalog No./ CAS No.

Quantity

Price

1,3-Dichloropropan-2-ol

1,3-Dichloropropan-2-ol

677427
96-23-1

1X250MG

Please log in.

D5-1,3-Dichloropropan-2-ol

D5-1,3-Dichloropropan-2-ol

685547
1173020-20-6

1X25MG

Please log in.

Safety Data Sheetaccording to Regulation (EC) No 1907/2006 (REACH)
Classifications according to Regulation (EC) No 1272/2008.
Printdate 02.12.2024
IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
Product name:D5-1,3-Dichloropropan-2-ol
Catalog No.:685547
Relevant identified uses of the substance or mixtureIdentified: Laboratory chemical
uses: R&D
Uses advised against:HPC Standards GmbH
Am Wieseneck 7

04451 Cunnersdorf
Deutschland


Tel. +49 34291 3372-36
Fax. +49 34291 3372-39
contact@hpc-standards.com
Emergency telephone numberHPC Standards Tel. +49 34291 3372-36
This number is only available during office hours.
HAZARDS IDENTIFICATION2.1 Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008
Carcinogenicity (Category 1B), H350
Acute toxicity, Oral (Category 3), H301
Acute toxicity, Dermal (Category 4), H312
Label elements
PictogramGHS06 skull
skull
GHS08 silhouete
silhouete
2.2 Label elements
Labelling according Regulation (EC) No 1272/2008
Pictogram Signal word Danger
Hazard statement(s)
H301 Toxic if swallowed.
H312 Harmful in contact with skin.
H350 May cause Cancer Precautionary statement(s)
P201 Obtain special instructions before use.
P280 Wear protective gloves/ protective clothing.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/doctor.
P308 + P313 IF exposed or concerned: Get medical advice/ attention.
Supplemental Hazard
Statements
none
Restricted to professional users.
2.3 Other hazards - none
COMPOSITION/INFORMATION ON INGREDIENTS3.1 Substances
Synonyms : 1,3-Dichloro-2-propanol-d5
Formula : C3HD5Cl2O
Molecular weight : 133,92 g/mol
CAS-No. : 1173020-20-6
Index-No. : 602-064-00-0
Hazardous ingredients according to Regulation (EC) No 1272/2008
Component Classification Concentration
1,3-Dichloroisopropyl-d5 alcohol
CAS-No.
Index-No.
1173020-20-6
602-064-00-0
Carc. 1B; Acute Tox. 3; Acute
Tox. 4; H350, H301, H312
<= 100 %
FormulaC3HCl2D5O
Molecular Weight (g/mol)134.02
CAS-No.1173020-20-6
FIRST AID MEASURES4.1 Description of first aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician.
In case of eye contact
Flush eyes with water as a precaution.
If swallowed
Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with
water. Consult a physician.
4.2 Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in
section 11
4.3 Indication of any immediate medical attention and special treatment needed
No data available
FIRE-FIGHTING MEASURES5.1 Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide 5.2 Special hazards arising from the substance or mixture
Hydrogen chloride gas
5.3 Advice for firefighters
Wear self-contained breathing apparatus for firefighting if necessary.
5.4 Further information
Use water spray to cool unopened containers
ACCIDENTAL RELEASE MEASURES6.1 Personal precautions, protective equipment and emergency procedures
Wear respiratory protection. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Remove
all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form
explosive concentrations. Vapours can accumulate in low areas.
For personal protection see section 8.
6.2 Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
6.3 Methods and materials for containment and cleaning up
Contain spillage, and then collect with an electrically protected vacuum cleaner or by wet-brushing and
place in container for disposal according to local regulations (see section 13). Keep in suitable, closed
containers for disposal.
6.4 Reference to other sections
For disposal see section 13.
HANDLING AND STORAGE7.1 Precautions for safe handling
Avoid exposure - obtain special instructions before use.Avoid contact with skin and eyes. Avoid inhalation
of vapour or mist.
Keep away from sources of ignition - No smoking.Take measures to prevent the build up of electrostatic
charge.
For precautions see section 2.2.
7.2 Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are
opened must be carefully resealed and kept upright to prevent leakage.
Store under inert gas. hygroscopic
Storage class (TRGS 510): 6.1B: Non-combustible, acute toxic Cat. 1 and 2 / very toxic hazardous
materials
7.3 Specific end use(s)
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
EXPOSURE CONTROLS/PERSONAL PROTECTION8.1 Control parameters
Ingredients with workplace control parameters
8.2 Exposure controls
Personal protective equipment
Eye/face protection
Use equipment for eye protection tested and approved under appropriate
government standards such as NIOSH (US) or EN 166(EU). Safety glasses
Skin protection
required
Body Protection
protective clothing
Respiratory protection
required when vapours/aerosols are generated.
Our recommendations on filtering respiratory protection are based on the following
standards: DIN EN 143, DIN 14387 and other accompanying standards relating to
the used respiratory protection system.
Recommended Filter type: Filter type ABEK
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory
protective devices are carried out according to the instructions of the producer.
These measures have to be properly documented.
Control of environmental exposure
Do not let product enter drains.
PHYSICAL AND CHEMICAL PROPERTIES9.1 Information on basic physical and chemical properties
a) Appearance Form: liquid
Colour: colourless
b) Odour No data available
c) Odour Threshold No data available
d) pH No data available
e) Melting point/freezing
point
Melting point/range: -4 °C - lit.
f) Initial boiling point and
boiling range
174,3 °C - lit.
g) Flash point 85 °C - closed cup
h) Evaporation rate No data available
i) Flammability (solid, gas) No data available
j) Upper/lower
flammability or
explosive limits
No data available
k) Vapour pressure No data available
l) Vapour density No data available
m) Relative density 1,417 g/mL at 25 °C1,417 g/cm3 at 25 °C
n) Water solubility No data available
o) Partition coefficient: noctanol/
water
No data available
p) Auto-ignition
temperature
No data available
q) Decomposition
temperature
No data available
r) Viscosity No data available s) Explosive properties No data available
t) Oxidizing properties No data available 9.2 Other safety information
No data available
STABILITY AND REACTIVITY10.1 Reactivity
No data available
10.2 Chemical stability
Stable
Stable under recommended storage conditions.
10.3 Possibility of hazardous reactions
No data available
10.4 Conditions to avoid
Heat, flames and sparks.
10.5 Incompatible materials
No data available
10.6 Hazardous decomposition products
Hazardous decomposition products formed under fire conditions. - Hydrogen chloride gas
Other decomposition products - No data available
In the event of fire: see section 5
TOXICOLOGICAL INFORMATION11.1 Information on toxicological effects
Acute toxicity
No data available
Skin corrosion/irritation
No data available
Serious eye damage/eye irritation
Respiratory or skin sensitisation
No data available
Germ cell mutagenicity
Carcinogenicity
Possible human carcinogen
Reproductive toxicity
Specific target organ toxicity - single exposure
No data available
Specific target organ toxicity - repeated exposure
No data available
Aspiration hazard
No data available
Additional Information
RTECS: Not available
To the best of our knowledge, the chemical, physical, and toxicological properties have not been
thoroughly investigated
ECOLOGICAL INFORMATION12.1 Toxicity
No data available 12.2 Persistence and degradability
No data available
12.3 Bioaccumulative potential
No data available
12.4 Mobility in soil
No data available(1,3-Dichloroisopropyl-d5 alcohol)
12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
12.6 Other adverse effects
No data available
DISPOSAL CONSIDERATIONS13.1 Waste treatment methods
Product
This combustible material may be burned in a chemical incinerator equipped with an afterburner and
scrubber. Offer surplus and non-recyclable solutions to a licensed disposal company.
Contaminated packaging
Dispose of as unused product
TRANSPORT INFORMATION14.1 UN number
ADR/RID: 2750 IMDG: 2750 IATA: 2750
14.2 UN proper shipping name
ADR/RID: 1,3-DICHLOROPROPANOL-2
IMDG: 1,3-DICHLOROPROPANOL-2
IATA: 1,3-Dichloropropanol-2
14.3 Transport hazard class(es)
ADR/RID: 6.1 IMDG: 6.1 IATA: 6.1
14.4 Packaging group
ADR/RID: II IMDG: II IATA: II
14.5 Environmental hazards
ADR/RID: no IMDG Marine pollutant: no IATA: no
14.6 Special precautions for user
No data available
REGULATORY INFORMATION15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
15.2 Chemical safety assessment
For this product a chemical safety assessment was not carried out
OTHER INFORMATIONThe above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any
guarantee of the properties of the product. For lab use only!