Safety Data Sheetaccording to Regulation (EC) No 1907/2006 (REACH)
Classifications according to Regulation (EC) No 1272/2008.
Printdate 22.12.2024
IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
Product name:Tridecafluoroheptanoic acid
Catalog No.:676368
Relevant identified uses of the substance or mixtureIdentified: Laboratory chemical
uses: R&D
Uses advised against:HPC Standards GmbH
Am Wieseneck 7

04451 Cunnersdorf
Deutschland


Tel. +49 34291 3372-36
Fax. +49 34291 3372-39
contact@hpc-standards.com
Emergency telephone numberHPC Standards Tel. +49 34291 3372-36
This number is only available during office hours.
HAZARDS IDENTIFICATION2.1 Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008
Acute toxicity, Oral (Category 4), H302
Skin corrosion (Category 1B), H314 Classification according to EU Directives 67/548/EEC or 1999/45/EC
C Corrosive R22, R34
Label elements
PictogramGHS05 acid
acid
GHS07 exclam
exclam
Signal word Danger
Hazard statement(s)
H302 Harmful if swallowed.
H314 Causes severe skin burns and eye damage Precautionary statement(s)
P280 Wear protective gloves/ protective clothing/ eye protection/ face
protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove
contact lenses, if present and easy to do. Continue rinsing.
P310 Immediately call a POISON CENTER or doctor/ physician.
Supplemental Hazard
Statements
none
2.3 Other hazards - none
COMPOSITION/INFORMATION ON INGREDIENTS3.1 Substances
Formula : C7HF13O2
Molecular Weight : 364,06 g/mol
CAS-No. : 375-85-9
EC-No. : 206-798-9
Hazardous ingredients according to Regulation (EC) No 1272/2008
Component Classification Concentration
Perfluoroheptanoic acid
CAS-No.
EC-No.
375-85-9
206-798-9
Acute Tox. 4; Skin Corr. 1B;
H302, H314
<= 100 %
Hazardous ingredients according to Directive 1999/45/EC
Component Classification Concentration
Perfluoroheptanoic acid
CAS-No.
EC-No.
375-85-9
206-798-9
C, R22 - R34 <= 100 %
FormulaC7HF13O2
Molecular Weight (g/mol)364.06
CAS-No.375-85-9
FIRST AID MEASURES4.1 Description of first aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. Consult a
physician.
In case of eye contact
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed
Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with
water. Consult a physician.
4.2 Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in
section 11
4.3 Indication of any immediate medical attention and special treatment needed
no data available
FIRE-FIGHTING MEASURES5.1 Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
5.2 Special hazards arising from the substance or mixture
Carbon oxides, Hydrogen fluoride
Carbon oxides, Hydrogen fluoride
5.3 Advice for firefighters
Wear self contained breathing apparatus for fire fighting if necessary.
5.4 Further information
no data available
ACCIDENTAL RELEASE MEASURES6.1 Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure
adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust.
For personal protection see section 8.
6.2 Environmental precautions
Do not let product enter drains.
6.3 Methods and materials for containment and cleaning up
Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed
containers for disposal.
6.4 Reference to other sections
For disposal see section 13.
HANDLING AND STORAGE7.1 Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols.
Provide appropriate exhaust ventilation at places where dust is formed.Normal measures for preventive fire
protection.
For precautions see section 2.2.
7.2 Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
7.3 Specific end use(s)
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
EXPOSURE CONTROLS/PERSONAL PROTECTION8.1 Control parameters
Components with workplace control parameters
8.2 Exposure controls
Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and
at the end of workday.
Personal protective equipment
Eye/face protection
Face shield and safety glasses Use equipment for eye protection tested and approved under
appropriate government standards such as NIOSH (US) or EN 166(EU). Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry Hands. Body Protection
Complete suit protecting against chemicals, The type of protective equipment must be selected
according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face particle
respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering
controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use
respirators and components tested and approved under appropriate government standards such
as NIOSH (US) or CEN (EU).
Control of environmental exposure
Do not let product enter drains.
PHYSICAL AND CHEMICAL PROPERTIES9.1 Information on basic physical and chemical properties
a) Appearance Form: crystalline
Colour: beige
b) Odour no data available
c) Odour Threshold no data available
d) pH no data available
e) Melting point/freezing
point
Melting point/freezing point: 30 °C
f) Initial boiling point and
boiling range
175 °C at 989 hPa
g) Flash point > 113,00 °C - closed cup
h) Evapouration rate no data available
i) Flammability (solid, gas) no data available
j) Upper/lower
flammability or
explosive limits
no data available
k) Vapour pressure no data available
l) Vapour density no data available
m) Relative density 1,792 g/mL at 25 °C
n) Water solubility no data available
o) Partition coefficient: noctanol/
water
no data available
p) Auto-ignition
temperature
no data available
q) Decomposition
temperature
no data available
r) Viscosity no data available
s) Explosive properties no data available t) Oxidizing properties no data available
9.2 Other safety information
no data available
STABILITY AND REACTIVITY10.1 Reactivity
no data available
10.2 Chemical stability
Stable under recommended storage conditions.
10.3 Possibility of hazardous reactions
no data available
10.4 Conditions to avoid
no data available
10.5 Incompatible materials
Strong oxidizing agents
10.6 Hazardous decomposition products
Other decomposition products - no data available
In the event of fire: see section 5
TOXICOLOGICAL INFORMATION11.1 Information on toxicological effects
Acute toxicity
no data available
Skin corrosion/irritation
no data available
Serious eye damage/eye irritation
no data available
Respiratory or skin sensitisation
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
IARC: No component of this product present at levels greater than or equal to 0.1% is identified as
probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity
no data available
Specific target organ toxicity - single exposure
no data available
Specific target organ toxicity - repeated exposure
no data available
Aspiration hazard
no data available
Additional Information
RTECS: Not available
ECOLOGICAL INFORMATION12.1 Toxicity
no data available 12.2 Persistence and degradability
no data available
12.3 Bioaccumulative potential
no data available
12.4 Mobility in soil
no data available
12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
12.6 Other adverse effects
no data available
DISPOSAL CONSIDERATIONS13.1 Waste treatment methods
Product
Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed
professional waste disposal service to dispose of this material. Dissolve or mix the material with a
combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.
Contaminated packaging
Dispose of as unused product
TRANSPORT INFORMATION14.1 UN number
ADR/RID: 3261 IMDG: 3261 IATA: 3261
14.2 UN proper shipping name
ADR/RID: CORROSIVE SOLID, ACIDIC, ORGANIC, N.O.S. (Perfluoroheptanoic acid)
IMDG: CORROSIVE SOLID, ACIDIC, ORGANIC, N.O.S. (Perfluoroheptanoic acid)
IATA: Corrosive solid, acidic, organic, n.o.s. (Perfluoroheptanoic acid)
14.3 Transport hazard class(es)
ADR/RID: 8 IMDG: 8 IATA: 8
14.4 Packaging group
ADR/RID: II IMDG: II IATA: II
14.5 Environmental hazards
ADR/RID: no IMDG Marine pollutant: no IATA: no
14.6 Special precautions for user
no data available
REGULATORY INFORMATIONThis safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
no data available
15.2 Chemical Safety Assessment
For this product a chemical safety assessment was not carried out
OTHER INFORMATIONThe above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any
guarantee of the properties of the product. For lab use only!