US Shop

New user? / Forgot your password?

0 Item | 0,00 €

Filter

Lincomycin hydrochloride

Item number677234
CAS859-18-7
FormulaC18H35ClN2O6S
Molecular weight443,00 g/mol
Quantity 1X250MG
storage conditions4 °C
CoA / MSDSRetrieve CoA
Retrieve MSDS
Lincomycin hydrochloride

Price

Please log in.

Product Variations:

Product

Catalog No./ CAS No.

Quantity

Price

Lincomycin hydrochloride

Lincomycin hydrochloride

677234
859-18-7

1X250MG

Please log in.

Safety Data Sheetaccording to Regulation (EC) No 1907/2006 (REACH)
Classifications according to Regulation (EC) No 1272/2008.
Printdate 13.12.2024
IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
Product name:Lincomycin hydrochloride
Catalog No.:677234
Relevant identified uses of the substance or mixtureIdentified: Laboratory chemical
uses: R&D
Uses advised against:HPC Standards GmbH
Am Wieseneck 7

04451 Cunnersdorf
Deutschland


Tel. +49 34291 3372-36
Fax. +49 34291 3372-39
contact@hpc-standards.com
Emergency telephone numberHPC Standards Tel. +49 34291 3372-36
This number is only available during office hours.
HAZARDS IDENTIFICATION2.1 Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008
Skin irritation (Category 2), H315
Eye irritation (Category 2), H319
Specific target organ toxicity - single exposure (Category 3), Respiratory system, H335
Label elements
PictogramGHS07 exclam
exclam
2.2 Label elements
Labelling according Regulation (EC) No 1272/2008
Signal Word Warning
Hazard statement(s)
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H335 May cause respiratory irritation.
Precautionary statement(s)
P261 Avoid breathing dust/ fume/ gas/ mist/ vapors/ spray.
P264 Wash skin thoroughly after handling.
P271 Use only outdoors or in a well-ventilated area.
P280 Wear protective gloves/ eye protection/ face protection.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes.
Remove contact lenses, if present and easy to do. Continue
rinsing.
Supplemental Hazard
Statements
none
Reduced Labeling (<= 125 ml)
Signal Word Warning
Hazard statement(s) none
Precautionary
statement(s)
none
Supplemental Hazard
Statements
none
2.3 Other hazards
This substance/mixture contains no components considered to be either persistent,
bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at
levels of 0.1% or higher.
COMPOSITION/INFORMATION ON INGREDIENTS3.1 Substances
Synonyms : Methyl 6,8-dideoxy-6-(1-methyl-4-propyl-2-
pyrrolidinecarboxamido)-1-thio-D-erythro-α-D-
galactooctopyranosidehydrochloride
Lincocinhydrochloride
Component: Methyl (2S-trans)-6,8-dideoxy-6-[[(1-methyl-4-propylpyrrolidin-2-yl)carbonyl]amino]-1-thio-D-erythro-α-D-galacto-octopyranoside monohydrochloride CAS-Nr. : 859-18-7 EC-Nr. : 212-726-7
Classification: Skin Irrit. 2; Eye Irrit. 2; STOT SE 3; H315, H319, H335
Concentration: <= 100 %
FormulaC18H35ClN2O6S
Molecular Weight (g/mol)443.00
CAS-No.859-18-7
FIRST AID MEASURES4.1 Description of first-aid measures
General advice
Show this material safety data sheet to the doctor in attendance.
If inhaled
After inhalation: fresh air.
In case of skin contact
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with
water/ shower.
In case of eye contact
After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact
lenses.
If swallowed
After swallowing: immediately make victim drink water (two glasses at most). Consult a
physician.
4.2 Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section
2.2) and/or in section 11
4.3 Indication of any immediate medical attention and special treatment needed
No data available
FIRE-FIGHTING MEASURES5.1 Extinguishing media
Suitable extinguishing media
Water Foam Carbon dioxide (CO2) Dry powder
Unsuitable extinguishing media
For this substance/mixture no limitations of extinguishing agents are given.
5.2 Special hazards arising from the substance or mixture
Carbon oxides
Nitrogen oxides (NOx)
Sulfur oxides
Hydrogen chloride gas
Combustible.
Development of hazardous combustion gases or vapours possible in the event of fire.
5.3 Advice for firefighters
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by
keeping a safe distance or by wearing suitable protective clothing.
5.4 Further information
Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire
extinguishing water from contaminating surface water or the ground water system.
ACCIDENTAL RELEASE MEASURES6.1 Personal precautions, protective equipment and emergency procedures
Advice for non-emergency personnel: Avoid inhalation of dusts. Avoid substance contact.
Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures,
consult an expert.
For personal protection see section 8.
6.2 Environmental precautions
Do not let product enter drains.
6.3 Methods and materials for containment and cleaning up
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions
(see sections 7 and 10). Take up dry. Dispose of properly. Clean up affected area. Avoid
generation of dusts.
6.4 Reference to other sections
For disposal see section 13.
HANDLING AND STORAGE7.1 Precautions for safe handling
For precautions see section 2.2.
7.2 Conditions for safe storage, including any incompatibilities
Storage conditions
Tightly closed. Dry.
Storage stability
Recommended storage temperature
2 - 8 °C
Storage class
Storage class (TRGS 510): 11: Combustible Solids
7.3 Specific end use(s)
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
EXPOSURE CONTROLS/PERSONAL PROTECTION8.1 Control parameters
Ingredients with workplace control parameters
8.2 Exposure controls
Personal protective equipment
Eye/face protection
Use equipment for eye protection tested and approved under appropriate
government standards such as NIOSH (US) or EN 166(EU). Safety glasses
Body Protection
protective clothing
Respiratory protection
required when dusts are generated.
Our recommendations on filtering respiratory protection are based on the following
standards: DIN EN 143, DIN 14387 and other accompanying standards relating to
the used respiratory protection system.
Recommended Filter type: Filter type P2
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory
protective devices are carried out according to the instructions of the producer.
These measures have to be properly documented.
Control of environmental exposure
Do not let product enter drains.
PHYSICAL AND CHEMICAL PROPERTIES9.1 Information on basic physical and chemical properties
a) Physical state solid
b) Color No data available
c) Odor No data available
d) Melting
point/freezing point
No data available
e) Initial boiling point
and boiling range
No data available
f) Flammability (solid,
gas)
No data available
g) Upper/lower
flammability or
explosive limits
No data available
h) Flash point Not applicable
i) Autoignition
temperature
No data available
j) Decomposition
temperature
No data available
k) pH No data available
l) Viscosity Viscosity, kinematic: No data available
Viscosity, dynamic: No data available
m) Water solubility No data available
n) Partition coefficient:
n-octanol/water
No data available
o) Vapor pressure No data available
p) Density No data available
Relative density No data available
q) Relative vapor
density
No data available
r) Particle
characteristics
No data available
s) Explosive properties No data available
t) Oxidizing properties No data available
9.2 Other safety information
No data available
STABILITY AND REACTIVITY10.1 Reactivity
The following applies in general to flammable organic substances and mixtures: in
correspondingly fine distribution, when whirled up a dust explosion potential may generally
be assumed.
10.2 Chemical stability
The product is chemically stable under standard ambient conditions (room temperature) .
10.3 Possibility of hazardous reactions
No data available
10.4 Conditions to avoid
no information available
10.5 Incompatible materials
Strong oxidizing agents
10.6 Hazardous decomposition products
In the event of fire: see section 5
TOXICOLOGICAL INFORMATION11.1 Information on toxicological effects
Acute toxicity
LD50 Oral - Rat - > 5.000 mg/kg
Remarks: (RTECS)
Inhalation: No data available
Dermal: No data available
Skin corrosion/irritation
Causes skin irritation.
Serious eye damage/eye irritation
Causes serious eye irritation.
Respiratory or skin sensitization
No data available
Germ cell mutagenicity
No data available
Carcinogenicity
No data available
Reproductive toxicity
No data available
Specific target organ toxicity - single exposure
Inhalation - May cause respiratory irritation.
Specific target organ toxicity - repeated exposure
No data available
Aspiration hazard
No data available
11.2 Additional Information
Endocrine disrupting properties
Product:
Assessment : The substance/mixture does not contain
components considered to have endocrine
disrupting properties according to REACH Article
57(f) or Commission Delegated regulation (EU)
2017/2100 or Commission Regulation (EU)
2018/605 at levels of 0.1% or higher.
RTECS: RH6315000
Vomiting, Diarrhea, To the best of our knowledge, the chemical, physical, and toxicological
properties have not been thoroughly investigated.
ECOLOGICAL INFORMATION12.1 Toxicity
Toxicity to daphnia
and other aquatic
invertebrates
mortality EC50 - Daphnia magna (Water flea) - 379,39 mg/l - 72 h
Remarks: (ECOTOX Database)
12.2 Persistence and degradability
No data available
12.3 Bioaccumulative potential
No data available
12.4 Mobility in soil
No data available
12.5 Results of PBT and vPvB assessment
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at
levels of 0.1% or higher.
12.6 Endocrine disrupting properties Product:
Assessment : The substance/mixture does not contain components
considered to have endocrine disrupting properties
according to REACH Article 57(f) or Commission
Delegated regulation (EU) 2017/2100 or Commission
Regulation (EU) 2018/605 at levels of 0.1% or higher.
12.7 Other adverse effects
No data available
DISPOSAL CONSIDERATIONS13.1 Waste treatment methods
Product
See www.retrologistik.com for processes regarding the return of chemicals and
containers, or contact us there if you have further questions.
TRANSPORT INFORMATION14.1 UN number
ADR/RID: - IMDG: - IATA: -
14.2 UN proper shipping name
ADR/RID: Not dangerous goods
IMDG: Not dangerous goods
IATA: Not dangerous goods
14.3 Transport hazard class(es)
ADR/RID: - IMDG: - IATA: -
14.4 Packaging group
ADR/RID: - IMDG: - IATA: -
14.5 Environmental hazards
ADR/RID: no IMDG Marine pollutant: no IATA: no
14.6 Special precautions for user
Further information
Not classified as dangerous in the meaning of transport regulations.
REGULATORY INFORMATION15.1 Safety, health and environmental regulations/legislation specific for the
substance or mixture
This material safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006.
Other regulations
Take note of Dir 94/33/EC on the protection of young people at work.
15.2 Chemical Safety Assessment
For this product a chemical safety assessment was not carried out
OTHER INFORMATIONThe above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any