US Shop

New user? / Forgot your password?

0 Item | 0,00 €

Filter

Terbuthylazine

ISO 17034 Certified Reference Material

Item number690678
CAS5915-41-3
FormulaC9H16ClN5
Molecular weight229,71 g/mol
Quantity 1X100MG
storage conditions4 °C
CoA / MSDSRetrieve CoA
Retrieve MSDS
Terbuthylazine

Price

Please log in.

Part of Product groups:
Product Variations:

Product

Catalog No./ CAS No.

Quantity

Price

D5-Terbuthylazine

D5-Terbuthylazine

675942
222986-60-9

1X5MG

Please log in.

D5-Terbuthylazine solution
Concentration: 100 µg/ml
Solvent: Acetone

D5-Terbuthylazine solution

676698
222986-60-9

1X1ML

Please log in.

Terbuthylazine solution
Concentration: 100 µg/ml
Solvent: Acetonitrile

Terbuthylazine solution

673449
5915-41-3

1X5ML

Please log in.

ISO 17034 Reference Material

Terbuthylazine

Terbuthylazine

675471
5915-41-3

1X250MG

Please log in.

ISO 17034 Certified Reference Material

Terbuthylazine

Terbuthylazine

690678
5915-41-3

1X100MG

Please log in.

Safety Data Sheetaccording to Regulation (EC) No 1907/2006 (REACH)
Classifications according to Regulation (EC) No 1272/2008.
Printdate 30.12.2024
IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
Product name:Terbuthylazine
Catalog No.:690678
Relevant identified uses of the substance or mixtureIdentified: Laboratory chemical
uses: R&D
Uses advised against:HPC Standards GmbH
Am Wieseneck 7

04451 Cunnersdorf
Deutschland


Tel. +49 34291 3372-36
Fax. +49 34291 3372-39
contact@hpc-standards.com
Emergency telephone numberHPC Standards Tel. +49 34291 3372-36
This number is only available during office hours.
HAZARDS IDENTIFICATION2.1 Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008 [EU-GHS/CLP]
Acute toxicity, Oral (Category 4)
Acute toxicity, Inhalation (Category 4)
Acute aquatic toxicity (Category 1), H400
Classification according to EU Directives 67/548/EEC or 1999/45/EC
Harmful if swallowed.
Label elements
PictogramGHS07 exclam
exclam
GHS08 silhouete
silhouete
GHS09 Aquatic-pollut-red
Aquatic-pollut-red
Signal word Warning
Hazard statement(s)
H302 + H332 Harmful if swallowed or if inhaled
Precautionary statement(s) none
Supplemental Hazard
Statements
none
According to European Directive 67/548/EEC as amended.
Hazard symbol(s) R-phrase(s)
R22 Harmful if swallowed S-phrase(s)
S36 Wear suitable protective clothing.
2.3 Other hazards - none
COMPOSITION/INFORMATION ON INGREDIENTS3.1 Substances
Formula : C9H16ClN5
Molecular Weight : 229,71 g/mol
Component Concentration
Terbuthylazine
CAS-No.
EC-No.
5915-41-3
227-637-9
-
Hazardous ingredients according to Regulation (EC) No 1272/2008
Component Classification Concentration
Terbuthylazine
CAS-No.
EC-No.
5915-41-3
227-637-9
Acute Tox. 4; Aquatic Acute 1;
H302, H400
M-Factor - Aquatic Acute: 10
For the full text of the H-Statements mentioned in this Section, see Section 15.
FormulaC9H16ClN5
Molecular Weight (g/mol)229.71
CAS-No.5915-41-3
FIRST AID MEASURES4.1 Description of first aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Consult a physician.
In case of eye contact
Flush eyes with water as a precaution.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
4.2 Most important symptoms and effects, both acute and delayed
4.3 Indication of any immediate medical attention and special treatment needed
no data available
FIRE-FIGHTING MEASURES5.1 Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
5.2 Special hazards arising from the substance or mixture
Carbon oxides, nitrogen oxides (NOx), Hydrogen chloride gas
Nature of decomposition products not known.
Carbon oxides, nitrogen oxides (NOx), Hydrogen chloride gas
5.3 Advice for firefighters
Wear self contained breathing apparatus for fire fighting if necessary.
5.4 Further information
no data available
ACCIDENTAL RELEASE MEASURES6.1 Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure
adequate ventilation. Avoid breathing dust.
6.2 Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the
environment must be avoided 6.3 Methods and materials for containment and cleaning up
Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed
containers for disposal.
6.4 Reference to other sections
For disposal see section 13
HANDLING AND STORAGE7.1 Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols.
Provide appropriate exhaust ventilation at places where dust is formed.Normal measures for preventive fire
protection.
7.2 Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
7.3 Specific end uses
no data available
EXPOSURE CONTROLS/PERSONAL PROTECTION8.1 Control parameters
Components with workplace control parameters
8.2 Exposure controls
Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and
at the end of workday.
Personal protective equipment
Eye/face protection
Safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested
and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands. Body Protection
Complete suit protecting against chemicals, The type of protective equipment must be selected
according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
For nuisance exposures use type P95 (US) or type P1 (EU EN 143) particle respirator.For higher
level protection use type OV/AG/P99 (US) or type ABEK-P2 (EU EN 143) respirator cartridges.
Use respirators and components tested and approved under appropriate government standards
such as NIOSH (US) or CEN (EU).
PHYSICAL AND CHEMICAL PROPERTIES9.1 Information on basic physical and chemical properties
a) Appearance Form: solid
b) Odour no data available
c) Odour Threshold no data available
d) pH no data available
e) Melting point/freezing
point
no data available
f) Initial boiling point and
boiling range
no data available
g) Flash point 100 °C - closed cup
h) Evaporation rate no data available
i) Flammability (solid, gas) no data available
j) Upper/lower
flammability or
explosive limits
no data available
k) Vapour pressure 2,0 hPa at 20 °C
l) Vapour density no data available
m) Relative density no data available
n) Water solubility insoluble
o) Partition coefficient: noctanol/
water
no data available
p) Autoignition
temperature
no data available
q) Decomposition
temperature
no data available
r) Viscosity no data available
s) Explosive properties no data available
t) Oxidizing properties no data available
9.2 Other safety information
no data available
STABILITY AND REACTIVITY10.1 Reactivity
no data available
10.2 Chemical stability
no data available
10.3 Possibility of hazardous reactions
no data available 10.4 Conditions to avoid
no data available
10.5 Incompatible materials
Strong oxidizing agents
10.6 Hazardous decomposition products
Other decomposition products - no data available
TOXICOLOGICAL INFORMATION11.1 Information on toxicological effects
Acute toxicity
LD50 Oral - rat - 1.845 mg/kg
LC50 Inhalation - rat - 4 h - > 3.510 mg/m3
LD50 Dermal - rabbit - > 3.000 mg/kg
Skin corrosion/irritation
no data available
Serious eye damage/eye irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
IARC: No component of this product present at levels greater than or equal to 0.1% is identified as
probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity
no data available
Specific target organ toxicity - single exposure
no data available
Specific target organ toxicity - repeated exposure
no data available
Aspiration hazard
no data available
Potential health effects
Inhalation Harmful if inhaled. May cause respiratory tract irritation.
Ingestion Harmful if swallowed.
Skin May be harmful if absorbed through skin. May cause skin irritation.
Eyes May cause eye irritation.
Additional Information
RTECS: XY4550000
ECOLOGICAL INFORMATION12.1 Toxicity
Toxicity to fish LC50 - Poecilia reticulata (guppy) - 1,6 mg/l - 96 h
Toxicity to daphnia and
other aquatic
invertebrates
EC50 - Daphnia magna (Water flea) - > 5 mg/l - 48 h
12.2 Persistence and degradability
no data available 12.3 Bioaccumulative potential
no data available
12.4 Mobility in soil
no data available
12.5 Results of PBT and vPvB assessment
no data available
12.6 Other adverse effects
Toxic to aquatic life.
no data available
DISPOSAL CONSIDERATIONS13.1 Waste treatment methods
Product
Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed
professional waste disposal service to dispose of this material. Dissolve or mix the material with a
combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.
Contaminated packaging
Dispose of as unused product.
TRANSPORT INFORMATION14.1 UN number
ADR/RID: - IMDG: - IATA: -
14.2 UN proper shipping name
ADR/RID: Not dangerous goods
IMDG: Not dangerous goods
IATA: Not dangerous goods
14.3 Transport hazard class(es)
ADR/RID: - IMDG: - IATA: -
14.4 Packaging group
ADR/RID: - IMDG: - IATA: -
14.5 Environmental hazards
ADR/RID: no IMDG Marine pollutant: no IATA: no
14.6 Special precautions for user
no data available
REGULATORY INFORMATIONThis safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
no data available
15.2 Chemical Safety Assessment
no data available

Full text of H-Statements referred to under sections 2 and 3.
H302 Harmful if swallowed.
H400 Very toxic to aquatic life.
OTHER INFORMATIONThe above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any
guarantee of the properties of the product. For lab use only!