US Shop

New user? / Forgot your password?

0 Item | 0,00 €

Propazine

ISO 17034 Reference Material

Item number676576
CAS139-40-2
FormulaC9H16ClN5
Molecular weight229,71 g/mol
Quantity 1X250MG
storage conditions4 °C
CoA / MSDSRetrieve CoA
Retrieve MSDS
Propazine

Price

Please log in.

Part of Product groups:
Product Variations:

Product

Catalog No./ CAS No.

Quantity

Price

D7-Propazine solution
Concentration: 100 µg/ml
Solvent: Acetonitrile

D7-Propazine solution

681833

1X1ML

Please log in.

D7-Propazine

D7-Propazine

681839

1X10MG

Please log in.

ISO 17034 Reference Material

Propazine

Propazine

676576
139-40-2

1X250MG

Please log in.

ISO 17034 Certified Reference Material

Propazine

Propazine

691769
139-40-2

1X100MG

Please log in.

Safety Data Sheetaccording to Regulation (EC) No 1907/2006 (REACH)
Classifications according to Regulation (EC) No 1272/2008.
Printdate 08.09.2024
IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
Product name:Propazine
Catalog No.:676576
Relevant identified uses of the substance or mixtureIdentified: Laboratory chemical
uses: R&D
Uses advised against:HPC Standards GmbH
Am Wieseneck 7

04451 Cunnersdorf
Deutschland


Tel. +49 34291 3372-36
Fax. +49 34291 3372-39
contact@hpc-standards.com
Emergency telephone numberHPC Standards Tel. +49 34291 3372-36
This number is only available during office hours.
HAZARDS IDENTIFICATION2.1 Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008
Carcinogenicity (Category 2), H351
Acute aquatic toxicity (Category 1), H400
Chronic aquatic toxicity (Category 1), H410
Label elements
PictogramGHS08 silhouete
silhouete
GHS09 Aquatic-pollut-red
Aquatic-pollut-red
2.2 Label elements
Labelling according Regulation (EC) No 1272/2008
Pictogram Signal word Warning
Hazard statement(s)
H351 Suspected of causing cancer.
H410 Very toxic to aquatic life with long lasting effects. Precautionary statement(s)
P280 Wear protective gloves/ protective clothing/ eye protection/ face
protection.
Supplemental Hazard
Statements
none
2.3 Other hazards
This substance/mixture contains no components considered to be either persistent, bioaccumulative and
toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
COMPOSITION/INFORMATION ON INGREDIENTS3.1 Substances
Synonyms : 2,4-Bis(isopropylamino)-6-chloro-1,3,5-triazine
Formula : C9H16ClN5
Molecular weight : 229,71 g/mol
CAS-No. : 139-40-2
EC-No. : 205-359-9
Index-No. : 613-067-00-1
Hazardous ingredients according to Regulation (EC) No 1272/2008
Component Classification Concentration
2-Chloro-4,6-bis(isopropylamino)-1,3,5-triazine
CAS-No.
EC-No.
Index-No.
139-40-2
205-359-9
613-067-00-1
Carc. 2; Aquatic Acute 1;
Aquatic Chronic 1; H351,
H400, H410
M-Factor - Aquatic Acute: 1
<= 100 %
FormulaC9H16ClN5
Molecular Weight (g/mol)229.71
CAS-No.139-40-2
FIRST AID MEASURES4.1 Description of first aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Consult a physician.
In case of eye contact
Flush eyes with water as a precaution.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
4.2 Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in
section 11
4.3 Indication of any immediate medical attention and special treatment needed
No data available
FIRE-FIGHTING MEASURES5.1 Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
5.2 Special hazards arising from the substance or mixture
No data available
5.3 Advice for firefighters
Wear self-contained breathing apparatus for firefighting if necessary.
5.4 Further information
No data available
ACCIDENTAL RELEASE MEASURES6.1 Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure
adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust.
For personal protection see section 8.
6.2 Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the
environment must be avoided.
6.3 Methods and materials for containment and cleaning up
Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed
containers for disposal.
6.4 Reference to other sections
For disposal see section 13
HANDLING AND STORAGE7.1 Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols.
Provide appropriate exhaust ventilation at places where dust is formed.
For precautions see section 2.2.
7.2 Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
Storage class (TRGS 510): Non Combustible Solids
7.3 Specific end use(s)
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
EXPOSURE CONTROLS/PERSONAL PROTECTION8.1 Control parameters
Components with workplace control parameters
8.2 Exposure controls
Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and
at the end of workday.
Personal protective equipment
Eye/face protection
Safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested
and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands. Body Protection
Impervious clothing, The type of protective equipment must be selected according to the
concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face particle
respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering
controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use
respirators and components tested and approved under appropriate government standards such
as NIOSH (US) or CEN (EU).
Control of environmental exposure
Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into
the environment must be avoided.
PHYSICAL AND CHEMICAL PROPERTIES9.1 Information on basic physical and chemical properties
a) Appearance Form: powder
Colour: white
b) Odour No data available
c) Odour Threshold No data available
d) pH No data available
e) Melting point/freezing
point
Melting point/range: 192,5 - 216 °C - OECD Test Guideline 102
f) Initial boiling point and
boiling range
- OECD Test Guideline 103Decomposes below the boiling point.
g) Flash point No data available
h) Evaporation rate No data available
i) Flammability (solid, gas) not auto-flammable j) Upper/lower
flammability or
explosive limits
No data available
k) Vapour pressure No data available
l) Vapour density No data available
m) Relative density 1,18 g/cm3 at 20 °C
n) Water solubility 0,003 g/l at 20 °C - OECD Test Guideline 105 - slightly soluble
o) Partition coefficient: noctanol/
water
log Pow: 3,01 at 25 °C
p) Auto-ignition
temperature
< 400 °C
q) Decomposition
temperature
No data available
r) Viscosity No data available
s) Explosive properties Not explosive
t) Oxidizing properties The product has been shown not to be oxidizing in a test following Directive
67/548/EEC (Method A17, Oxidizing properties).
9.2 Other safety information
Surface tension 72 mN/m at 20 °C
STABILITY AND REACTIVITY10.1 Reactivity
No data available
10.2 Chemical stability
Stable under recommended storage conditions.
10.3 Possibility of hazardous reactions
No data available
10.4 Conditions to avoid
No data available
10.5 Incompatible materials
Strong oxidizing agents
10.6 Hazardous decomposition products
Hazardous decomposition products formed under fire conditions. - Carbon oxides, Nitrogen oxides (NOx),
Hydrogen chloride gas
Other decomposition products - No data available
In the event of fire: see section 5
TOXICOLOGICAL INFORMATION11.1 Information on toxicological effects
Acute toxicity
LD50 Oral - Rat - male and female - > 7.700 mg/kg
LD50 Dermal - Rabbit - > 10.200 mg/kg
Skin corrosion/irritation
Skin - Rabbit
Result: Mild skin irritation
Serious eye damage/eye irritation
Eyes - Rabbit
Result: No eye Irritation Respiratory or skin sensitisation
No data available
Germ cell mutagenicity
reverse mutation assay
S. typhimurium
Result: negative
Carcinogenicity
Carcinogenicity - Mouse - Oral
Tumorigenic:Equivocal tumorigenic agent by RTECS criteria. Lungs, Thorax, or Respiration:Tumors.
Blood:Tumors.
Carcinogenicity - Rat - Oral
Tumorigenic:Neoplastic by RTECS criteria. Skin and Appendages: Other: Tumors.
Limited evidence of a carcinogenic effect.
Reproductive toxicity
Reproductive toxicity - Rat - Oral
Maternal Effects: Other effects. Effects on Embryo or Fetus: Fetotoxicity (except death, e.g., stunted fetus).
Specific target organ toxicity - single exposure
No data available
Specific target organ toxicity - repeated exposure
No data available
Aspiration hazard
No data available
Additional Information
RTECS: XY5300000
To the best of our knowledge, the chemical, physical, and toxicological properties have not been
thoroughly investigated.
ECOLOGICAL INFORMATION12.1 Toxicity
Toxicity to fish LC50 - Poecilia reticulata (guppy) - 3,7 mg/l - 7,0 d
Toxicity to daphnia and
other aquatic
invertebrates
EC50 - Daphnia magna (Water flea) - 11 mg/l - 48 h
Toxicity to algae static test EC50 - Pseudokirchneriella subcapitata - 0,362 mg/l - 72 h
12.2 Persistence and degradability
Biodegradability aerobic - Exposure time 28 d
Result: 6 % - Not readily biodegradable.
(OECD Test Guideline 301B)
12.3 Bioaccumulative potential
No data available
12.4 Mobility in soil
No data available
12.5 Results of PBT and vPvB assessment
This substance/mixture contains no components considered to be either persistent, bioaccumulative and
toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
12.6 Other adverse effects
Very toxic to aquatic life with long lasting effects
DISPOSAL CONSIDERATIONS13.1 Waste treatment methods
Product
Offer surplus and non-recyclable solutions to a licensed disposal company. Dissolve or mix the material
with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.
Contaminated packaging
Dispose of as unused product.
TRANSPORT INFORMATION14.1 UN number
ADR/RID: 3077 IMDG: 3077 IATA: 3077
14.2 UN proper shipping name
ADR/RID: ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (2-Chloro-4,6-
bis(isopropylamino)-1,3,5-triazine)
IMDG: ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (2-Chloro-4,6-
bis(isopropylamino)-1,3,5-triazine)
IATA: Environmentally hazardous substance, solid, n.o.s. (2-Chloro-4,6-bis(isopropylamino)-1,3,5-
triazine)
14.3 Transport hazard class(es)
ADR/RID: 9 IMDG: 9 IATA: 9
14.4 Packaging group
ADR/RID: III IMDG: III IATA: III
14.5 Environmental hazards
ADR/RID: yes IMDG Marine pollutant: yes IATA: yes
14.6 Special precautions for user
Further information
EHS-Mark required (ADR 2.2.9.1.10, IMDG code 2.10.3) for single packagings and combination
packagings containing inner packagings with Dangerous Goods > 5L for liquids or > 5kg for solids
REGULATORY INFORMATION15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
15.2 Chemical safety assessment
For this product a chemical safety assessment was not carried out
OTHER INFORMATIONThe above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any
guarantee of the properties of the product. For lab use only!