New user? / Forgot your password?
0 Item | 0,00 €
Item number | 674860 |
CAS | 13598-36-2 |
Formula | H3O3P |
Molecular weight | 82,00 g/mol |
Quantity | 1X250MG |
storage conditions | 20 °C |
CoA / MSDS | Retrieve CoA Retrieve MSDS |
Product | Catalog No./ CAS No. | Quantity | Price | |
---|---|---|---|---|
674860 | 1X250MG | Please log in. | ||
Phosphonic acid solution | 690430 | 1X1ML | Please log in. |
Safety Data Sheet | according to Regulation (EC) No 1907/2006 (REACH) Classifications according to Regulation (EC) No 1272/2008. Printdate 03.12.2024 |
IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING | |
Product name: | Phosphonic acid |
Catalog No.: | 674860 |
Relevant identified uses of the substance or mixture | Identified: Laboratory chemical uses: R&D |
Uses advised against: | HPC Standards GmbH Am Wieseneck 7 04451 Cunnersdorf Deutschland Tel. +49 34291 3372-36 Fax. +49 34291 3372-39 contact@hpc-standards.com |
Emergency telephone number | HPC Standards Tel. +49 34291 3372-36 This number is only available during office hours. |
HAZARDS IDENTIFICATION | 2.1 Classification of the substance or mixture Classification according to Regulation (EC) No 1272/2008 Corrosive to metals (Category 1), H290 Acute toxicity, Oral (Category 4), H302 Skin corrosion (Category 1A), H314 Classification according to EU Directives 67/548/EEC or 1999/45/EC C Corrosive R35 Xn Harmful R22 |
Label elements | |
Pictogram | GHS05 acid acid GHS07 exclam exclam |
Signal word Danger Hazard statement(s) H290 May be corrosive to metals. H302 Harmful if swallowed. H314 Causes severe skin burns and eye damage. Precautionary statement(s) P280 Wear protective gloves/ protective clothing/ eye protection/ face protection. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310 Immediately call a POISON CENTER or doctor/ physician. Supplemental Hazard Statements none 2.3 Other hazards This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher. | |
COMPOSITION/INFORMATION ON INGREDIENTS | 3.1 Substances Synonyms : Phosphonic acid Formula : H3O3P Molecular weight : 82,00 g/mol CAS-No. : 13598-36-2 EC-No. : 237-066-7 Index-No. : 015-157-00-0 Hazardous ingredients according to Regulation (EC) No 1272/2008 Component Classification Concentration Phosphorous acid CAS-No. EC-No. Index-No. 13598-36-2 237-066-7 015-157-00-0 Met. Corr. 1; Acute Tox. 4; Skin Corr. 1A; H290, H302, H314 <= 100 % Hazardous ingredients according to Directive 1999/45/EC Component Classification Concentration Phosphorous acid CAS-No. EC-No. Index-No. 13598-36-2 237-066-7 015-157-00-0 C, R22 - R35 <= 100 % |
Formula | H3O3P |
Molecular Weight (g/mol) | 82.00 |
CAS-No. | 13598-36-2 |
FIRST AID MEASURES | 4.1 Description of first aid measures General advice Consult a physician. Show this safety data sheet to the doctor in attendance. If inhaled If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician. In case of skin contact Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. Consult a physician. In case of eye contact Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician. If swallowed Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician. 4.2 Most important symptoms and effects, both acute and delayed The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11 4.3 Indication of any immediate medical attention and special treatment needed No data available |
FIRE-FIGHTING MEASURES | 5.1 Extinguishing media Suitable extinguishing media Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. 5.2 Special hazards arising from the substance or mixture Oxides of phosphorus 5.3 Advice for firefighters Wear self contained breathing apparatus for fire fighting if necessary. 5.4 Further information The product itself does not burn. |
ACCIDENTAL RELEASE MEASURES | 6.1 Personal precautions, protective equipment and emergency procedures Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. 6.2 Environmental precautions Do not let product enter drains. 6.3 Methods and materials for containment and cleaning up Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal. 6.4 Reference to other sections For disposal see section 13. |
HANDLING AND STORAGE | 7.1 Precautions for safe handling Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Provide appropriate exhaust ventilation at places where dust is formed. 7.2 Conditions for safe storage, including any incompatibilities Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Store under inert gas. Air sensitive. 7.3 Specific end uses no data available |
EXPOSURE CONTROLS/PERSONAL PROTECTION | 8.1 Control parameters Components with workplace control parameters 8.2 Exposure controls Appropriate engineering controls Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday. Personal protective equipment Eye/face protection Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Skin protection Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. Body Protection Complete suit protecting against chemicals, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Respiratory protection Where risk assessment shows air-purifying respirators are appropriate use a full-face particle respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU). |
PHYSICAL AND CHEMICAL PROPERTIES | 9.1 Information on basic physical and chemical properties a) Appearance Form: crystalline Colour: white b) Odour No data available c) Odour Threshold No data available d) pH < 1,0 at 20 |
STABILITY AND REACTIVITY | 10.1 Reactivity no data available 10.2 Chemical stability no data available 10.3 Possibility of hazardous reactions no data available 10.4 Conditions to avoid no data available 10.5 Incompatible materials Strong bases, Oxidizing agents, Metals 10.6 Hazardous decomposition products Other decomposition products - no data available |
TOXICOLOGICAL INFORMATION | 11.1 Information on toxicological effects Acute toxicity LD50 Oral - Rat - female - 1.560 mg/kg (OECD Test Guideline 401) Skin corrosion/irritation Skin - Rabbit Result: Corrosive Serious eye damage/eye irritation No data available Respiratory or skin sensitisation No data available Germ cell mutagenicity No data available Carcinogenicity IARC: No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC. Reproductive toxicity No data available Specific target organ toxicity - single exposure No data available Specific target organ toxicity - repeated exposure No data available Aspiration hazard No data available Additional Information RTECS: SZ6400000 burning sensation, Cough, wheezing, laryngitis, Shortness of breath, spasm, inflammation and edema of the larynx, spasm, inflammation and edema of the bronchi, pneumonitis, pulmonary edema, Material is extremely destructive to tissue of the mucous membranes and upper respiratory tract, eyes, and skin. |
ECOLOGICAL INFORMATION | 12.1 Toxicity 12.2 Persistence and degradability no data available 12.3 Bioaccumulative potential no data available 12.4 Mobility in soil no data available 12.5 Results of PBT and vPvB assessment no data available 12.6 Other adverse effects no data available May be harmful to aquatic organisms due to the shift of the pH. |
DISPOSAL CONSIDERATIONS | 13.1 Waste treatment methods Product Offer surplus and non-recyclable solutions to a licensed disposal company. Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber. Contaminated packaging Dispose of as unused product. |
TRANSPORT INFORMATION | 14.1 UN number ADR/RID: 2834 IMDG: 2834 IATA: 2834 14.2 UN proper shipping name ADR/RID: PHOSPHOROUS ACID IMDG: PHOSPHOROUS ACID IATA: Phosphorous acid 14.3 Transport hazard class(es) ADR/RID: 8 IMDG: 8 IATA: 8 14.4 Packaging group ADR/RID: III IMDG: III IATA: III 14.5 Environmental hazards ADR/RID: yes IMDG Marine pollutant: yes IATA: no 14.6 Special precautions for user no data available |
REGULATORY INFORMATION | This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006. 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture no data available 15.2 Chemical Safety Assessment no data available |
OTHER INFORMATION | The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. For lab use only! |