US Shop

New user? / Forgot your password?

0 Item | 0,00 €

Filter

2,4'-DDD

ISO 17034 Certified Reference Material

Item number690141
CAS53-19-0
FormulaC14H10Cl4
Molecular weight320,04 g/mol
Quantity 1X50MG
storage conditions4 °C
CoA / MSDSRetrieve CoA
Retrieve MSDS
2,4'-DDD

Price

Please log in.

Part of Product groups:

 

 

Product Variations:

Product

Catalog No./ CAS No.

Quantity

Price

ISO 17034 Reference Material

2,4'-DDD

2,4'-DDD

674986
53-19-0

1X100MG

Please log in.

2,4'-DDD solution
Concentration: 100 µg/ml
Solvent: Acetonitrile

2,4'-DDD solution

678377
53-19-0

1X5ML

Please log in.

ISO 17034 Certified Reference Material

2,4'-DDD

2,4'-DDD

690141
53-19-0

1X50MG

Please log in.

4,4'-DDD solution
Concentration: 100 µg/ml
Solvent: Ethyl acetate

4,4'-DDD solution

673530
72-54-8

1X5ML

Please log in.

4,4'-DDD

4,4'-DDD

677528
72-54-8

1X250MG

Please log in.

4,4'-DDD solution
Concentration: 100 µg/ml
Solvent: Acetonitrile

4,4'-DDD solution

678378
72-54-8

1X5ML

Please log in.

4,4'-DDD solution
Concentration: 10.0 µg/ml
Solvent: Cyclohexane

4,4'-DDD solution

679107
72-54-8

1X10ML

On request

4,4'-DDD solution
Concentration: 10.0 µg/ml
Solvent: Acetonitrile

4,4'-DDD solution

687884
72-54-8

1X10ML

Please log in.

D8-4,4'-DDD solution
Concentration: 100 µg/ml
Solvent: Acetone

D8-4,4'-DDD solution

684690
93952-20-6

1X1ML

Please log in.

Safety Data Sheetaccording to Regulation (EC) No 1907/2006 (REACH)
Classifications according to Regulation (EC) No 1272/2008.
Printdate 27.12.2024
IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
Product name:2,4'-DDD
Catalog No.:690141
Relevant identified uses of the substance or mixtureIdentified: Laboratory chemical
uses: R&D
Uses advised against:HPC Standards GmbH
Am Wieseneck 7

04451 Cunnersdorf
Deutschland


Tel. +49 34291 3372-36
Fax. +49 34291 3372-39
contact@hpc-standards.com
Emergency telephone numberHPC Standards Tel. +49 34291 3372-36
This number is only available during office hours.
HAZARDS IDENTIFICATION2.1 Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008 [EU-GHS/CLP]
Carcinogenicity (Category 2)
Classification according to EU Directives 67/548/EEC or 1999/45/EC
Limited evidence of a carcinogenic effect.
Label elements
PictogramGHS08 silhouete
silhouete
Signal word Warning
Hazard statement(s)
H351 Suspected of causing cancer.
Precautionary statement(s)
P281 Use personal protective equipment as required.
Supplemental Hazard
Statements
none
According to European Directive 67/548/EEC as amended.
Hazard symbol(s) R-phrase(s)
R40 Limited evidence of a carcinogenic effect. S-phrase(s)
S36/37 Wear suitable protective clothing and gloves.
2.3 Other hazards - none
COMPOSITION/INFORMATION ON INGREDIENTS3.1 Substances
Synonyms : Mitotane
o,pŒ-DDD
1-(2-Chlorophenyl)-1-(4-chlorophenyl)-2,2-dichloroethane
(2,4Œ-Dichlorodiphenyl)dichloroethane
Formula : C14H10Cl4
Molecular Weight : 320,04 g/mol
Component Concentration
Mitotane
CAS-No.
EC-No.
53-19-0
200-166-6
-
FormulaC14H10Cl4
Molecular Weight (g/mol)320.04
CAS-No.53-19-0
FIRST AID MEASURES4.1 Description of first aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Consult a physician.
In case of eye contact
Flush eyes with water as a precaution.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
4.2 Most important symptoms and effects, both acute and delayed
4.3 Indication of any immediate medical attention and special treatment needed
no data available
FIRE-FIGHTING MEASURES5.1 Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
5.2 Special hazards arising from the substance or mixture
Carbon oxides, Hydrogen chloride gas
5.3 Advice for firefighters
Wear self contained breathing apparatus for fire fighting if necessary.
5.4 Further information
no data available
ACCIDENTAL RELEASE MEASURES6.1 Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure
adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. 6.2 Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
6.3 Methods and materials for containment and cleaning up
Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed
containers for disposal.
6.4 Reference to other sections
For disposal see section 13.
HANDLING AND STORAGE7.1 Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols.
Provide appropriate exhaust ventilation at places where dust is formed.Normal measures for preventive fire
protection.
7.2 Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
7.3 Specific end use(s)
no data available
EXPOSURE CONTROLS/PERSONAL PROTECTION8.1 Control parameters
Components with workplace control parameters
8.2 Exposure controls
Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and
at the end of workday.
Personal protective equipment
Eye/face protection
Safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested
and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands. Body Protection
impervious clothing, The type of protective equipment must be selected according to the
concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face particle
respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering
controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use
respirators and components tested and approved under appropriate government standards such
as NIOSH (US) or CEN (EU).
PHYSICAL AND CHEMICAL PROPERTIES9.1 Information on basic physical and chemical properties
a) Appearance Form: crystalline
Colour: white
b) Odour no data available
c) Odour Threshold no data available
d) pH no data available
e) Melting point/freezing
point
Melting point/range: 77 - 78 ‹C - lit.
f) Initial boiling point and
boiling range
no data available
g) Flash point no data available
h) Evaporation rate no data available
i) Flammability (solid, gas) no data available
j) Upper/lower
flammability or
explosive limits
no data available
k) Vapour pressure no data available
l) Vapour density no data available
m) Relative density no data available
n) Water solubility no data available
o) Partition coefficient: noctanol/
water
no data available
p) Auto-ignition
temperature
no data available
q) Decomposition
temperature
no data available
r) Viscosity no data available
s) Explosive properties no data available
t) Oxidizing properties no data available
9.2 Other safety information
no data available
STABILITY AND REACTIVITY10.1 Reactivity
no data available
10.2 Chemical stability
no data available 10.3 Possibility of hazardous reactions
no data available
10.4 Conditions to avoid
no data available
10.5 Incompatible materials
Strong oxidizing agents, Strong bases
10.6 Hazardous decomposition products
Other decomposition products - no data available
TOXICOLOGICAL INFORMATION11.1 Information on toxicological effects
Acute toxicity
LD50 Oral - rat - > 5.000 mg/kg
Skin corrosion/irritation
no data available
Serious eye damage/eye irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
This product is or contains a component that has been reported to be possibly carcinogenic based on its
IARC, ACGIH, NTP, or EPA classification.
Limited evidence of carcinogenicity in animal studies
IARC: 2B - Group 2B: Possibly carcinogenic to humans (Mitotane)
Reproductive toxicity
no data available
Specific target organ toxicity - single exposure
no data available
Specific target organ toxicity - repeated exposure
no data available
Aspiration hazard
no data available
Potential health effects Inhalation May be harmful if inhaled. May cause respiratory tract irritation.
Ingestion May be harmful if swallowed.
Skin May be harmful if absorbed through skin. May cause skin irritation.
Eyes May cause eye irritation.
Additional Information
RTECS: KH7880000
ECOLOGICAL INFORMATION12.1 Toxicity
no data available
12.2 Persistence and degradability
no data available 12.3 Bioaccumulative potential
no data available
12.4 Mobility in soil
no data available
12.5 Results of PBT and vPvB assessment
no data available
12.6 Other adverse effects
no data available
DISPOSAL CONSIDERATIONS13.1 Waste treatment methods
Product
Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed
professional waste disposal service to dispose of this material. Dissolve or mix the material with a
combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.
Contaminated packaging
Dispose of as unused product.
TRANSPORT INFORMATION14.1 UN number
ADR/RID: - IMDG: - IATA: -
14.2 UN proper shipping name
ADR/RID: Not dangerous goods
IMDG: Not dangerous goods
IATA: Not dangerous goods
14.3 Transport hazard class(es)
ADR/RID: - IMDG: - IATA: -
14.4 Packaging group
ADR/RID: - IMDG: - IATA: -
14.5 Environmental hazards
ADR/RID: no IMDG Marine Pollutant: no IATA: no
14.6 Special precautions for user
no data available
REGULATORY INFORMATIONThis safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
no data available
15.2 Chemical Safety Assessment
no data available
OTHER INFORMATIONThe above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any
guarantee of the properties of the product. For lab use only!