New user? / Forgot your password?
0 Item | 0,00 €
Item number | 675425 |
CAS | 67-47-0 |
Formula | C6H6O3 |
Molecular weight | 126,11 g/mol |
Quantity | 1X100MG |
storage conditions | 4 °C |
CoA / MSDS | Retrieve CoA Retrieve MSDS |
Product | Catalog No./ CAS No. | Quantity | Price | |
---|---|---|---|---|
675425 | 1X100MG | Please log in. |
Safety Data Sheet | according to Regulation (EC) No 1907/2006 (REACH) Classifications according to Regulation (EC) No 1272/2008. Printdate 27.11.2024 |
IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING | |
Product name: | 5-(Hydroxymethyl)-2-furaldehyde |
Catalog No.: | 675425 |
Relevant identified uses of the substance or mixture | Identified: Laboratory chemical uses: R&D |
Uses advised against: | HPC Standards GmbH Am Wieseneck 7 04451 Cunnersdorf Deutschland Tel. +49 34291 3372-36 Fax. +49 34291 3372-39 contact@hpc-standards.com |
Emergency telephone number | HPC Standards Tel. +49 34291 3372-36 This number is only available during office hours. |
HAZARDS IDENTIFICATION | 2.1 Classification of the substance or mixture Classification according to Regulation (EC) No 1272/2008 Skin irritation (Category 2), H315 Eye irritation (Category 2), H319 Specific target organ toxicity - single exposure (Category 3), Respiratory system, H335 Classification according to EU Directives 67/548/EEC or 1999/45/EC Xi Irritant R36/37/38 |
Label elements | |
Pictogram | GHS07 exclam exclam |
Labelling according Regulation (EC) No 1272/2008 Pictogram Signal word Warning Hazard statement(s) H315 Causes skin irritation. H319 Causes serious eye irritation. H335 May cause respiratory Irritation Precautionary statement(s) P261 Avoid breathing dust. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Supplemental Hazard Statements none 2.3 Other hazards This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher | |
COMPOSITION/INFORMATION ON INGREDIENTS | 3.1 Substances Synonyms : 5-Hydroxymethyl-2-furancarboxaldehyde 5-(Hydroxymethyl)furfural Formula : C6H6O3 Molecular weight : 126,11 g/mol CAS-No. : 67-47-0 EC-No. : 200-654-9 Hazardous ingredients according to Regulation (EC) No 1272/2008 Component Classification Concentration 5-(Hydroxymethyl)-2-furaldehyde CAS-No. EC-No. 67-47-0 200-654-9 Skin Irrit. 2; Eye Irrit. 2; STOT SE 3; H315, H319, H335 <= 100 % Hazardous ingredients according to Directive 1999/45/EC Component Classification Concentration 5-(Hydroxymethyl)-2-furaldehyde CAS-No. EC-No. 67-47-0 200-654-9 Xi, R36/37/38 <= 100 % |
Formula | C6H6O3 |
Molecular Weight (g/mol) | 126.11 |
CAS-No. | 67-47-0 |
FIRST AID MEASURES | 4.1 Description of first aid measures General advice Consult a physician. Show this safety data sheet to the doctor in attendance. If inhaled If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician. In case of skin contact Wash off with soap and plenty of water. Consult a physician. In case of eye contact Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician. If swallowed Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician. 4.2 Most important symptoms and effects, both acute and delayed The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11 4.3 Indication of any immediate medical attention and special treatment needed No data available |
FIRE-FIGHTING MEASURES | 5.1 Extinguishing media Suitable extinguishing media Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. 5.2 Special hazards arising from the substance or mixture Carbon oxides 5.3 Advice for firefighters Wear self-contained breathing apparatus for firefighting if necessary. 5.4 Further information No data available |
ACCIDENTAL RELEASE MEASURES | 6.1 Personal precautions, protective equipment and emergency procedures Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8. 6.2 Environmental precautions Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided. 6.3 Methods and materials for containment and cleaning up Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal. 6.4 Reference to other sections For disposal see section 13. |
HANDLING AND STORAGE | 7.1 Precautions for safe handling Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2. 7.2 Conditions for safe storage, including any incompatibilities Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Recommended storage temperature 2 - 8 °C Light sensitive. Store under inert gas. Storage class (TRGS 510): Non Combustible Solids 7.3 Specific end use(s) Apart from the uses mentioned in section 1.2 no other specific uses are stipulated |
EXPOSURE CONTROLS/PERSONAL PROTECTION | 8.1 Control parameters Components with workplace control parameters 8.2 Exposure controls Appropriate engineering controls Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday Personal protective equipment Eye/face protection Safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Skin protection Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching gloves outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. Body Protection impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Respiratory protection For nuisance exposures use type P95 (US) or type P1 (EU EN 143) particle respirator.For higher level protection use type OV/AG/P99 (US) or type ABEK-P2 (EU EN 143) respirator cartridges. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU). Control of environmental exposure Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided. |
PHYSICAL AND CHEMICAL PROPERTIES | 9.1 Information on basic physical and chemical properties a) Appearance Form: solid b) Odour No data available c) Odour Threshold No data available d) pH No data available e) Melting point/freezing point No data available f) Initial boiling point and boiling range 114 - 116 °C at 1 hPa - lit. g) Flash point 79 °C - closed Cup h) Evaporation rate No data available i) Flammability (solid, gas) No data available j) Upper/lower flammability or explosive limits No data available k) Vapour pressure No data available l) Vapour density No data available m) Relative density 1,243 g/mL at 25 °C n) Water solubility No data available o) Partition coefficient: noctanol/ water No data available p) Auto-ignition temperature No data available q) Decomposition temperature No data available r) Viscosity No data available s) Explosive properties No data available t) Oxidizing properties No data available 9.2 Other safety information No data available |
STABILITY AND REACTIVITY | 10.1 Reactivity No data available 10.2 Chemical stability Stable under recommended storage conditions. 10.3 Possibility of hazardous reactions No data available 10.4 Conditions to avoid No data available 10.5 Incompatible materials Strong bases, Strong oxidizing agents, Strong reducing agents 10.6 Hazardous decomposition products Other decomposition products - No data available In the event of fire: see section 5 |
TOXICOLOGICAL INFORMATION | 11.1 Information on toxicological effects Acute toxicity LD50 Oral - Rat - 2.500 mg/kg Remarks: Behavioral:Convulsions or effect on seizure threshold. Skin corrosion/irritation No data available Serious eye damage/eye irritation No data available Respiratory or skin sensitisation No data available Germ cell mutagenicity Hamster Lungs Cytogenetic analysis Carcinogenicity Carcinogenicity - Rat - Subcutaneous Tumorigenic:Equivocal tumorigenic agent by RTECS criteria. Kidney, Ureter, Bladder:Kidney tumors. IARC: No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC. Reproductive toxicity No data available Specific target organ toxicity - single exposure Inhalation - May cause respiratory irritation. Specific target organ toxicity - repeated exposure No data available Aspiration hazard No data available Additional Information RTECS: LT7031100 To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated. |
ECOLOGICAL INFORMATION | 12.1 Toxicity Toxicity to daphnia and other aquatic invertebrates LC50 - Daphnia magna (Water flea) - 34 mg/l - 72 h 12.2 Persistence and degradability No data available 12.3 Bioaccumulative potential No data available 12.4 Mobility in soil No data available 12.5 Results of PBT and vPvB assessment This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher. 12.6 Other adverse effects Harmful to aquatic life. No data available |
DISPOSAL CONSIDERATIONS | 13.1 Waste treatment methods Product Offer surplus and non-recyclable solutions to a licensed disposal company. Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber. Contaminated packaging Dispose of as unused product |
TRANSPORT INFORMATION | 14.1 UN number ADR/RID: - IMDG: - IATA: - 14.2 UN proper shipping name ADR/RID: Not dangerous goods IMDG: Not dangerous goods IATA: Not dangerous goods 14.3 Transport hazard class(es) ADR/RID: - IMDG: - IATA: - 14.4 Packaging group ADR/RID: - IMDG: - IATA: - 14.5 Environmental hazards ADR/RID: no IMDG Marine pollutant: no IATA: no 14.6 Special precautions for user No data available |
REGULATORY INFORMATION | This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006. 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture No data available 15.2 Chemical Safety Assessment For this product a chemical safety assessment was not carried out |
OTHER INFORMATION | The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. For lab use only! |